Email: info@ecoheatonline.com Phone: (315) 386-2878 Fax: (315) 386-3009
Leading the way to clean, efficient and renewable heating comfort
This link leads to a page with lots of information about the EKO LINE BOILER, as well as my personal experience and some other stuff
EKO LINE Brochure
Cast Iron FD-42
EKO Pellet Boilers
BioMax Boilers
EKO Line Boilers
Woodboilers
Goliath Boilers
Breakdown Tanks
DanfossThermic Valve
Timesaver Pipe
EKO Line User Manual
BioMax Brochure
Goliath Boiler Brochure
Cast Iron FD-42 Brochure
Boiler Technology
Fuel Technology
Piping Diagrams
EKO Line boilers provide a convenient, safe and environmentally friendly way to heat your home and domestic hot water with wood. EKO boilers assure the independence and self-reliance that heating with wood provides.

Because the boilers use wood gasification combustion, they give unusually high overall heating efficiency. They use substantially less wood than conventional boilers and outdoor water stoves with no visible smoke when fully operating.

EKO boilers burn so clean, they are safer (virtually no risk of a chimney fire) and result in cleaner air for everyone. They also help to substantially reduce greenhouse gas emissions. EKO Line boilers enable you to increase the warm security of your home in a safe, environmentally responsible way.
Click on image to play video
Boiler construction - elements
Boiler construction - materials
eko001002.jpg
EKO-Line boilers may be used for heating any kind of building. They are mostly used in one-family houses, drying houses, workshops, halls, or greenhouses. However, boiler placement is not limited to these applications; the above are just examples of where EKO-Line boilers have worked with success.
Boiler output should be based on a building’s heat demand, calculated by a qualified central heating designer. To select the appropriate boiler, the a/m calculated value should be increased by 20%. If this calculation isn't performed, boiler sizing may be chosen using the heat factor in relation to m3 of building cubature. Heat factor values should be determined as 30-50 W/m3 depending on heat insulation.
Technical Data for EKO-Line Boilers
Parameters
Unit
EKO-Line 25
EKO-Line 40
EKO-Line 60
EKO-Line 80
Power range
kBtu
85
137
205
275
Weight
Lb
1280
1390
2070
2712
Height
A inch
51.5
59
60.5
60.5
Height of heating water exit
B inch
48.5
56
56.5
56.5
Height of heating water entry
C inch
8.3
6.0
7.9
7.9
Height of outlet valve
D inch
5.1
2.7
5.1
5.1
Height of chimney flue
E inch
37.4
50.0
45.7
45.7
Width including handle
F inch
24.8
24.8
30.3
30.3
Width including casing
G inch
23.6
23.6
29.1
29.1
Depth
H inch
41.1
41.1
53.5
  1. 7
Hot water exit
I inch
12.6
12.6
24.0
24.0
Diameter of chimney flue
J mm
7.8
7.8
8.2
8.2
Diameter of hot water exit
inch
2.0
2.0
2.5
2.5
Diameter of hot water entry
inch
2.0
2.0
2.5
2.5
Kind of connection
-
thread
thread
flange
flange
Diameter of drain valve
inch
0.5
0.5
0.5
0.5
Water capacity
Gal
20
25
47
54
Volume of loading chamber (gasification)
Gal
31
49
82
123
Power consumption
W
50
50
100
100
Moisture of wood:
- recommended
%
15 - 25
- acceptable
%
10 - 35
Maximum log diameter
inch
7
7
7
7
Maximum length of logs
inch
20
20
25
25
Average flue gas temperature
F
340
Max. w orking pressure
PSI
25
Required chimney draught
Pa
15 - 20
Voltage / frequency
V/Hz
120V/60Hz
EKO-Line boilers are equipped with RK 2001 R4E enabling:
eko001001.jpg
1. Master switch
2. Boiler temperature indicator
3. Boiler fire-up mode indicator
4. Boiler overheating indicator
5. Room thermostat indicator
6. Boiler thermostat knob
7. Circulating pump indicator
8. Fuel shortage indicator
9. Room thermostat knob
Each boiler is able to work without room temperature sensor as well.
Basing information about boiler assembly
  1. Boiler placing. Boiler can be placed in the heating room, basement, or in an outside wood storage building. There should be enough space to accommodate fuel storage for the whole heating season.
  2. Boiler start-up rules Each boiler should be connected to the heating system of which the heating capacity equals that of the boiler output.
To protect the boiler against low-temperature corrosion the end-user should assure return temperature does
not reach lower than 120F. It is possible by installing of four way mixing valve.
Boiler has to be connected to the chimney duct in the smallest distance possible.
Chimney duct should be insulated to prevent condensation (low exhaust temperature).
The chimney should have the section and height assuring required chimney draught (see table).
Boiler
output
Chimney section
95k btu
8 inches
135k btu
8 inches
205k btu
8.25 inches
8.25 inches
275k btu
CLICK FOR EKO LINE BOILER PRICING
Home» HEAT and HOT WATER BOILERS » Wood Boilers » EKO-LINE BOILER